Self-winding extension cord

Good day to all. I bring to your attention my version of manufacturing a fairly convenient self-reeling extension cord from the parts of a "killed" imported vacuum cleaner.




On the Internet there are many options for similar designs, which used plastic scraps from the body of the vacuum cleaner itself. The idea was to make a completely independent device case from materials and parts that were readily available and at hand.


In this design used:
- Details from the PHILIPS vacuum cleaner.
- Two twin sockets 16A.
- The handle is furniture.
- LDSP 16 mm thick.
- Edge tape.
- Plywood 6mm thick.
- Coupler furniture 5X50mm.
- Screws with a diameter of 3.5mm.
- Fasteners M3, M4.
- Colorless varnish XB-784.

Of the tools used:
- A drill on a rack.
- Jigsaw.
- The grinding machine.
- Iron.
- Screwdriver, wire cutters, etc.

Used coil parts with wire from a vacuum cleaner.



Parts cut from laminated chipboard 210x80x16mm - 2pcs, 168x80x16mm - 2pcs, with holes and a handle. The inner surface of the wire holes and buttons are varnished.



Parts cut out of plywood with dimensions of 210x200x6mm with holes. Plywood is sanded and varnished.



Assembled body frame. Details are connected by furniture ties 5x50mm.






The back panel of the housing with mounting screws M4 and M3.



Rear panel of the housing with a fixed coil base. The base is fixed with M4 screws.



Coil assembly, wire fastening.




The front panel of the housing with an additional screw clamp for the axis of the coil.



Front panel of the housing with installed base sockets. The base of the outlets is secured with M4 screws.




Installation of the main elements of the device in the housing.




The lock release button is made of an aluminum rod with a diameter of 17.5 mm. The restrictive washer is cut out of the felt-tip pen body and is simply very tightly mounted on the shaft.

Self-winding extension cord


Extension cord assembly. The heads of screws and screeds are sealed with self-adhesive furniture plugs.



The length of the fully unwound wire is 9M. Case size (without sockets and handles) 210x200x92mm. The total power of the connected load is up to 2.2 kW.

If you need additional information, write to the post office, I will try to be sure to answer.
Feedback, suggestions and comments are very welcome.

8
8
8.3

Add a comment

    • smilesmilesxaxaokdontknowyahoonea
      bossscratchfoolyesyes-yesaggressivesecret
      sorrydancedance2dance3pardonhelpdrinks
      stopfriendsgoodgoodgoodwhistleswoontongue
      smokeclappingcraydeclarederisivedon-t_mentiondownload
      heatirefullaugh1mdameetingmoskingnegative
      not_ipopcornpunishreadscarescaressearch
      tauntthank_youthisto_clueumnikacuteagree
      badbeeeblack_eyeblum3blushboastboredom
      censoredpleasantrysecret2threatenvictoryyusun_bespectacled
      shokrespektlolprevedwelcomekrutoyya_za
      ya_dobryihelperne_huliganne_othodifludbanclose
84 commentary
Zhinka is not a cholovik! xaxa
... chicken is not a bird, Zaporozhets is not a car, but Colchis is not a tractor! )))))))
What does twisted pair signal transmission have to do with a bifilar?
Ferrite filters suppress only high-frequency common mode noise and do not suppress a useful differential signal.
But a hundred meters of an ordinary SHVVP wire in a low-frequency spectrum inductance too. Because .. read the wiki.
Inductance does not depend on the frequency of the signal passing through it.
Why do domestic and foreign manufacturers of equipment often indicate on the PSU board phase and zero, although in the socket, even with three contacts can be as you like, as an electrician connected.
It’s still “Europe hasn’t quite reached”))))). And look at the "Euro-players" - it’s different and you won’t include it in them, the "Euro socket"))). There is a place on top (“mother” for grounding, and not just on the side. A pin (“dad”) sticks out of the sockets with the ground.
They talked about the bifilar. You don’t know much about me yet, I have been doing and am doing the technique of transmitters and receivers of different ranges.
I transmitted over a twisted pair cable even a color video signal up to hundreds of meters.
And here it is. Look, you have a simple cable to the monitor, camera, it passes any modern device, it makes several turns around the ring, tube. Think special ferrite?
Yes. But a hundred meters of an ordinary SHVVP wire in a low-frequency spectrum inductance too. Because .. read the wiki.
igormask, You obviously did not read what I wrote. ((
Or read, but did not understand anything. ((
Your example no way not relevant to what I wrote.
igormask, You obviously did not read what I wrote. ((
Or read, but did not understand anything. ((
Your example no way not relevant to what I wrote.
Fortunately, no one will change anything, no strangers will be allowed there. Cable color coding - white and red. I connected the phase to white, otherwise “Sapienti sat”.
Most likely, this machine (Chinese or Turkish production) has more than once tripped, and the holding current is already much less. Or this automatic machine of another group (for example A or B) in which the response time is less.
And who determined this? Fire expert? So one of them frankly said to me, tanning inside is a short circuit, tanning is detected, arson, and it doesn’t matter that someone who has not extinguished the “goby” has thrown into a corner where there are no sockets. It’s easiest to blame for short-circuiting, and that an oiled rag, especially in the heat (and any rubbish including) can catch fire itself, to prove it is how much trouble.
I wonder who, where and when did the first publish nonsense about inductance in an extension cord?
There is this type of winding of transformer windings - bifilar. This is when the winding is made of two insulated wires. If one end is connected to the signal source, and the other is short-circuited (or the active load is turned on), then the current will flow in wires in different directions, i.e. towards each other. Thereby compensating each other's magnetic fields. The inductance of such a coil is practically 0. If someone does not agree, then read about the twisted pair wire used to transmit signals.
I’ll add, throwing wires is not a fact that I solved all the problems. Absolutely unfamiliar people - electricians will throw wires over the park. Heard a song, mixed up electrician wires over a park? Give to listen? No, I censor this site.
And then there’s such a nuance.One at the cottage did an electrician, access, video, television. I began to hand over the work to the Customer, and in the acceptance committee dissatisfied persons who mounted the hood for the house to him. They say you put a backlit switch in the garage, so when the lights are off in the garage, the fan keeps spinning. The customer supported this nonsense. Not handed over the work. It almost got to a fight. I found that the fans were screwed up, the blades rotate with a reverse air flow, 10 mA will never be able to rotate the 220 powerful hood motor. The customer accepted the work, paid.
igormask
which on x .. calculations. From life: a neighbor’s garage burned out. A refrigerator, clearly less than 1 kW, was connected to a reel extension. In the summer, in the heat, the wires first caught fire, the rubbish was different from them, and then the short circuit cut off the electricity. It is good that there was a man in the neighborhood and noticed smoke, called a fire.
R555
knocked out 63 A input circuit breaker
It seems that he was the most loaded, at the limit, the rest "with a margin"! scratch
igormask: the topic of siseg is not disclosed in
IF 2.2 kW is connected for a long time (more than 30-60 min (?), Then in the reeled-out extension cord (even half), and even packed in such a “cabinet”, overheating with all the consequences can occur from induction.
they switch zero in the switches of the fixtures,

I could not argue with one Armenian shabashnik (in fact, he was a mason-plasterer, but at the same time he also made an electrician) that he had to switch the phase, he argued: "Tada wakes the switch on," that the phase is connected in series on the drum from which direction he did not want to come and listen, referred to his own experience. Since this was done throughout the house, I just changed the phase and zero wires in the shield.
Yeah ! Familiar thing. No matter how much I didn’t explain to people about the danger of frail extensions, they don’t push the wire under the floor carpet, they will move office chairs and cut everything there. The most unpleasant thing is that the machine in the shield may not cut off, the carpet will burn the postings faster. I remembered along the way. One in the office was given a burglar alarm, other people mounted the shield. I asked where to power the control panel. We’ll find out now, he said. He opened the socket and shorted the contacts with a screwdriver. Bah! Flash! in the office the lights went out. Then I looked, the input automaton knocked out at 63 A. But those that seemed to be correct, to sockets, to lighting separately, did not work. The screwdriver has melted. Apparently, he always checks like that. And at home as well.
I read what they wrote here about the fact that in the Soviet amp the background went only in one position of the plug and Truth was revealed to me. It seems to be related to the network interference between the trance windings. Their mutual arrangement and capacity between the primary and secondary. If the pheasant is closer in the layers of the primary to the secondary, the background will be stronger. I remember disassembling Soviet transes and in some there was a so-called electrostatic screen, although there was no grounding in the apartments. And I agree with you in part, so that the collectors where the wires should be soldered. But stupidity is not cured. I drove my assistants - electricians and fined, because they switch zero in the switches of the fixtures, I explained about at least 2 reasons why this should not be done, they all switched one zero. You will come to hand over the work to the Customer, he has prepared the money, he is happy with everything, the light is on, you will not redo all the boxes ... So it is here. What's the point, everything was marked, assembled, and the electricians at the outlet plugged in whatever way.
Valery
when people take an extension cord for work, I think they know what kind of load they will include!
Yeah, you tell our accountants, or my wife! They buy the cheapest Chinese extension cords, put kettles and microwave ovens in them (specifically mine - an iron, a vacuum cleaner)! Although you are talking about peopleand Zhinka is not a cholovik! xaxa
R555
often indicate on the board BP phase and zero
Without claiming to be the truth, I think that this is done for illiterate assemblers soldering wires to the board, such as - blue - N! Perhaps this is a requirement of any technical specifications so that no other wires get into these holes on the board? scratch
I do not want to repeat myself, but if you are interested in issues with heating and inductance, then this was discussed in the comments on homemade My webpage. I also gave a comparative calculation of the heating from the active and inductive resistances of the cable.
Concerning the marking of wires, an example from Soviet times, when they did not think about marking, grounding and other zaum. I can’t remember exactly, but either the amplifier, or the tape recorder “fonil” when the plug was plugged into the network in one position, and stopped when the plug was “turned over”. Now, when we connected domestic gas boilers, we always marked on the plug what pin the phase was on, otherwise an error sometimes popped up and the boiler did not start. Most likely this is due to the fact that literally everything is crammed with various electronics and processors.
I agree that heat dissipation in the bay is worse, but in half a second so that it burns ... That our deceased extension cord was also very long, and when we wound it, we got a certain inductance, which even exerted an alternating current at a frequency of 50 Hz resistance, exacerbating heat. This is not nonsense, I later read about this effect in the literature more than once.
And so, yes, the cross-section of the wire must be calculated, the material of the core, the type of insulation, even the ambient temperature, otherwise at the output you can get 110 out of 220 with a small load.
By the way, I have a personal question for you, I don’t know and I won’t ask, everyone shrugs. Why do domestic and foreign manufacturers of equipment often indicate on the PSU board the phase and zero, although in the socket, even with three contacts can be anything like an electrician connected. And if the plug is ordinary, it can be turned on anyway. I can’t understand why they mark the input wires of the power supply unit ...
It is heated the same way! Equally !!! COOLED in different ways!
For the purity of the experiment, squeeze the unwound wire between two layers of polystyrene foam and work this way - it will also burn, although it is unwound.
In general, when people take an extension cord for work, they, I think, know what kind of load they will include! What power is both long-term or short-term. Accordingly, the length / cross section of the extension must somehow be selected, not?
... The fact that your extension cord, when it was wound into a bay, blazed up, only says that it was not picked up correctly - when it was unwound it was also a “heater” that heated the air, taking some of the energy from the consumer))) )
By the way, I recently showed a person 225 Volts on one side and 201 on the other side of his extension cord when working, when he said "Yes, do not get thicker! This one works fine!"
I want to say about the fact that the wire wound into a coil is supposedly heated no more than the unwound one. Stronger. My companions and I used the same extension cord for a long time with the same load. Then, for compactness, they wound a plastic reel from under the cable. Hacked - blazed along with the coil, barely put out. Once I bought an industrial extension cord just 5 m long, I read the instructions for nothing. And it says there. Do not rewind when using, do not rewind !!!
Quote: Guest ANDREW
it turns out a magnetic coil with interturn magnetic fields, wire heating and ignition will occur.

You have already written about sci-fi nonsense. And about heating and ignition - justification on the table! Imagine the calculation, otherwise you will be considered an irresponsible chatterbox. ((
Valery
But I think, why is this not giving electricity to wooden houses? !!!
Only for fire reasons! xaxa
But I think, why is this not giving electricity to wooden houses? !!! ))). They sit, poor, with kerosene ....))))
Is it three phase ??? )))) And if not, what kind of "magnetic coil" are we talking about ??? And what is "interturn magnetic fields" ??? This is such an expression, in order to show that its author is a dock in electrical engineering ?? ))))
P.S. Stop all of you already repeating this turbidity about "heating the coil" ... (It seems to be what current is, they taught everything at school! And then they "heard a ringing, but forgot on what principle this ringing can ring!"))) )) The heating of such a wire in the coil will not be stronger than its heating, when it is completely unwound! Another thing is that in the unwound state it is "blown by air", but in the unwound state - no!
By the way ... And the vacuum cleaner from which the coil was 100 watts in total ??? Or, nevertheless, more than a kilowatt, and, accordingly, the cross-section of the wire did he have this power?))))
Well, I don’t know where to get such parts from vacuum cleaners!

It is strange to see a man who has not met a single burnt vacuum cleaner in his life! )))))
Guest ANDREW
In this extension cord, it will be possible to poke out only bulbs of no more than 100 watts, or unwind the extension cord completely, otherwise a magnetic coil with inter-turn magnetic fields is obtained, the wire will heat up and ignite.
1
If you read further than the heading, at least the first paragraph, you would see:
I bring to your attention my version of manufacturing a fairly convenient self-reeling extension cord from the parts of a "killed" imported vacuum cleaner.

He died, for example, an engine.
Well, I don’t know where to get such parts from vacuum cleaners!
And I know - in the "dead" vacuum cleaners.
Unit for the idea;) Well, I don’t know where to get such parts from vacuum cleaners! I saw everything on sale, but this usually does not break or it breaks completely already with a vacuum cleaner, they don’t sell it.
And the rest - the author is well done!
The performance is great, but ergonomics suffer a bit. I had a diplomat without a handle; I screwed the door onto him with screws. And then I realized why diplomats have rotary handles. For an irrevocable wear is quite uncomfortable.